ADD: Suzhou Xiangcheng industrial director Wong Tai Ping Road 90
TEL:18015413905 18015413906
FAX:0512-65623905
E-mail:salesjsjzyx@163.com
WEB:http://www.tk97.cc |
|
|
|
HERE IS >> Industrial flaw detection apparatus
|
Industrial washing machine |
|
Jun Ze P Series Medical Film Processor
JZ-P14
|
JZ-P14A
|
|
|
JZ-P17
|
JZ-P17A
|
|
|
P14、P14A、P17Schematic diagram of
|
P17ASchematic diagram of
|
|
|
Latest generation JZ-P14/P17 is a desktop suitable for small and medium-sized washing the washing machine, the operation is very simple. High speed and efficiency, and precision computer-controlled, beautiful overall injection shape. It can be widely used in medical imaging centers, hospital clinical diagnosis, private clinics, animal hospitals, laboratories, and mobile vehicle. Schematic diagram of
|
1.Side panel design
|
The side panels with detachable design, user at a glance; maintenance, maintenance is more convenient. Side panel design
|
|
|
2.Reliable performance
|
Reliable microprocessor control procedures to ensure product quality. Further improve the temperature control of the computer, the accuracy of the speed control, whether you used continuously for long, it can easily do the job.
|
|
|
3.Control Panel
|
Knob to adjust the temperature and speed, relying on the film transport sensor can automatically complete the whole process of developing, fixing, washing and drying.
|
|
|
4.New send-chip board
|
Feeding board with a special set of new material (Japan Ling Yake force plate) to ensure that the film in the process of flushing non-stick film, thus ensuring the quality of the film wash; to avoid the film of a metal material to produce rust and static and impactrinse quality.
|
|
|
5.New PTC heating block
|
Using the new PTC heating instead of the previous heating wire, to ensure uniform drying hot air, film drying effect, and significantly longer service life.
|
|
|
6.Change the drain pipe location; bold washing the circulation line The past, I produced the P series washing machine, reference Brooklyn Tektronix, Germany washing machine drain pipe design in the front of the washing machine drain pipe; users accustomed to the rear of the washing machine operation,avoid sending films dirty clothes. Similarly, this design is easy to make a washing machine to wash films control is not good washing water flow resulting in significant, fixing drug contamination. Drain pipe on the back of the washing machine for the above problems our technical department, bold washing the circulation line. Change the drain pipe location; bold washing the circulation line
|
|
|
|
7.The protection of the microcomputer design
|
Baffle design to eliminate the significant, the fixing liquid steam erosion of the circuit board, thereby extending its life, this design also greatly facilitates the maintenance engineer.
|
|
|
8.The drive roller group
|
DuPont materials pouring the forming roller, acid, alkali, will not easily expand or crack, roller lifetime warranty. High strength dense arrangement of the type of roller to ensure secure transmission of the film of any size, and effectively prevent liquid splash.
|
|
|
9.Into the chip sensing probe
|
Using imported micro switch as the film advance sensor, reliable, simple and guaranteed.
|
|
|
10.The use of plastic film clips
|
To avoid rust and static electricity generated by the use of metal materials, greatly improving the quality of the film wash.
|
|
|
11.Increase the drug trough cover
|
Developing and fixing slot cover design to avoid cross-contamination of liquid to effectively prevent the natural oxidation of the liquid, to extend the usage time of the liquid.
|
|
|
12.Advanced heating system
|
The unique design of the heating system does not contact with the liquid, greatly extending the heating rods life.
|
|
+
|
13.Two-body fluid system
|
Automatic the catamaran supplement pump can be based on the number of washing their own fresh liquid, so that the working fluid is always kept fresh.
|
|
|
14."C "card
|
According to user response when cleaning washing machine roller group, "C" card is easy to fall into gear, the phenomenon of the card. According to this phenomenon, the technology sector, specializing in the import reinforced nylon material, and change its shape to solve problems, thus ensuring the safe operation of the film.
|
|
|
15.Automatic circulation system
|
Automatic circulation system allows the liquid concentration is consistent.
|
|
|
Jun Ze P Series comes standard with:
|
|
1.Developing fixing synchronization heating system
2.Developing fixing washing independent circulatory system
3.Developing fixing synchronization complement system
4.Electromagnetic valve-regulated water, water-saving system
5.Professional conical duct drying system
6.Mechanical sensing feed-chip system
7.The DKM electronic speed control energy-saving system
|
P-14 Technical parameters
|
Max processing width
|
350mm(14")
|
Wash Specification
|
Maximum wash width of 14 inches, minimum wash size 3 × 3 × 4 inches
|
Processed film variety
|
X-ray, CT, MRI and other medical film
|
Flush the whole process time
|
105/135/165s,±1s
|
Development time adjustment
|
25/35/45s
|
Hourly flushing volume
|
Developing 25 seconds: 14 x 17-inch and 80
|
Temperature regulation
|
Liquid:28℃~37℃ Drying:45℃~65℃(Automatic adjustment)
|
Liquid supplement method
|
, Automatic replenishment and manual complement each rinse 0.5 m2 supplementary time
|
Supplement the amount of adjustment
|
20ml~200ml
|
Flushing procedure
|
Developing, fixing, washing, drying time auto-complete
|
Liquid capacity
|
Ceramic heating device
Developing 5.2 liters, 5.2 liters of fixing
|
Washed control
|
Automatically controlled by a solenoid valve, to see the piece flush water, no piece rinse off
|
Power supply
|
220V/50Hz、8.8A; Power:2KW
|
Pipes interface
|
3/4Inch
|
Volume
|
770mm(Long)×590mm(Wide)×420mm(High) (Not even the chassis)
|
Weight
|
50Kg±1Kg
|
P-14A
Max processing width
|
350mm(14")
|
Wash Specification
|
Maximum wash width of 14 inches, minimum wash size 3 × 3 × 4inches
|
Processed film variety
|
X-ray, CT, MRI and other medical film
|
Flush the whole process time
|
90s~360s,±1s
|
Development time adjustment
|
20s~70s
|
Hourly flushing volume
|
Developing 20 seconds: 14 x 17-inch 120
|
Temperature regulation
|
Liquid:20℃~40℃ Drying:20℃~70℃
|
Liquid supplement method
|
, Automatic replenishment and manual complement each rinse 0.5 m2 supplementary time
|
Supplement the amount of adjustment
|
20ml~500ml
|
Flushing procedure
|
Developing, fixing, washing, drying time auto-complete
|
Liquid capacity
|
5.5 liters of the developing, fixing 5.5 l
|
Washed control
|
Automatically controlled by a solenoid valve, to see the piece flush water, no piece rinse off
|
Power supply
|
220V/50Hz、12A; Power:2.64KW
|
Pipes interface
|
3/4Inch
|
Volume
|
770mm(Long)×590mm(Wide)×420mm(High) (Not even the chassis)
|
Weight
|
50Kg±1Kg
|
P-17
Max processing width
|
450mm(17")
|
Wash Specification
|
Maximum wash width of 14 inches, minimum wash size 3 × 3 × 4inches
|
Processed film variety
|
X-ray, CT, MRI and other medical film
|
Flush the whole process time
|
105/135/165s,±1s
|
Development time adjustment
|
28/36/44s
|
Hourly flushing volume
|
Developing 28 seconds: 14 x 17-inch 110
|
Temperature regulation
|
Liquid:28℃~37℃ Drying:45℃~65℃(Automatic adjustment)
|
Liquid supplement method
|
, Automatic replenishment and manual complement each rinse 0.5 m2 supplementary time
|
Supplement the amount of adjustment
|
20ml~200ml
|
Flushing procedure
|
Developing, fixing, washing, drying time auto-complete
|
Liquid capacity
|
Developing 8 l 8 l, fixing
|
Washed control
|
Automatically controlled by a solenoid valve, to see the piece flush water, no piece rinse off
|
Power supply
|
220V/50Hz、10A; Power:2.2KW
|
Pipes interface
|
3/4Inch
|
Volume
|
770mm(Long)×690mm(Wide)×420mm(High) (Not even the chassis)
|
Weight
|
60Kg±1Kg
|
P-17A
Max processing width
|
450mm(17")
|
Wash Specification
|
Maximum wash width of 14 inches, minimum wash size 3 × 3 × 4inches
|
Processed film variety
|
X-ray, CT, MRI and other medical film
|
Flush the whole process time
|
90s~360s,±1s
|
Development time adjustment
|
20s~70s
|
Hourly flushing volume
|
Developing 28 seconds: 14 x 17-inch 240
|
Temperature regulation
|
Liquid:20℃~40℃ Drying:20℃~70℃
|
Liquid supplement method
|
, Automatic replenishment and manual complement each rinse 0.5 m2 supplementary time
|
Supplement the amount of adjustment
|
20ml~500ml
|
Flushing procedure
|
Developing, fixing, washing, drying time auto-complete
|
Liquid capacity
|
Developing 12.5 liters, 12.5 liters of fixing
|
Washed control
|
Automatically controlled by a solenoid valve, to see the piece flush water, no piece rinse off
|
Power supply
|
220V/50Hz、13A; Power:2.86KW
|
Pipes interface
|
3/4Inch
|
Volume
|
770mm(Long)×690mm(Wide)×450mm(High) (Not even the chassis)
|
Weight
|
70Kg±1Kg
|
|
|
|